Differences between monobloc & split system heat pumps

29 Jul.,2024

 

Differences between monobloc & split system heat pumps

Size variations between monobloc and split system air source heat pumps

For more information, please visit OUTES.

The monobloc air source heat pump is a single unit that is placed on the outside of the residential dwelling as close to the water supply of the dwelling&#;s heating system as possible. The footprint of the monobloc unit is larger than that of the outdoor unit of a split system air source heat pump. However, a split system also requires internal space to be available for the indoor unit that is placed inside the dwelling.

Flexibility of monobloc and split system air source heat pumps

Although both types of air source heat pump have the same basic components, the split system connects its two units together with pipes that transfer refrigerant between them. The outdoor unit captures heat from the air, and the indoor unit transfers that heat to the heating system of the dwelling. By contrast, the monobloc unit has a closed-circuit system for the refrigerant and it connects in a similar way to a conventional gas boiler to the hot and cold-water supply of the dwelling.

This difference means that monobloc units are better situated as close to the heating system as possible to limit the length of pipe required. As the pipes carry water, they need to be insulated to prevent freezing in the winter and limit heat loss from the warm water generated by the monobloc air source heat pump. Also, as the systems containing water are outside the building, they need to be protected from frost damage by the addition of anti-freeze.

For more information, please visit Monobloc Heat Pump.

With a split system air source heat pump, freezing is not an issue as all the components that handle water are housed within the indoor unit. The two parts of the split system are connected by refrigerant pipes, rather than water pipes, and the connection can be several metres long if required, leading to greater flexibility when positioning the outdoor unit further away from the dwelling.

The same refrigerants can be used in both monobloc and split system air source heat pumps, however, there are several types that are available for use. Always seek advice from the heat pump manufacturers on any health and safety issues with the refrigerant and check its global warming potential (GWP) for it impact on the environment.

THERMA V Monobloc - Air to Water Heat Pumps - HVAC

This function is disables on your cookie management.

To activate it, click on the link "Edit cookie settings" in the upper

right corner of this page.

For more Split system water heaterinformation, please contact us. We will provide professional answers.